Height and density describe different properties
A taller building is visually prominent, but its height alone does not tell us how much floor area it places on a given amount of land. Floor Area Ratio (FAR) relates floor area to site area. In this brief, nominal FAR is source-reported building or project area divided by the documented site area.
International Square in downtown Washington, DC has a broad, linked form with 12 main floors, a 152-foot architectural height, and a 120-foot occupied height. The Waterview in Rosslyn consists of a 24-story office building and a roughly 30-story hotel and condominium building joined on a common base. Its tallest point is approximately 300 feet.
Normalize each project by its own site
International Square’s reported building area is 1,185,122 square feet on a documented 105,818-square-foot site. The Waterview’s reported project area is 932,745 square feet on a 94,204-square-foot site. International Square therefore has 27.1% more reported floor area, while its site is 12.3% larger.
Dividing each numerator by its own site denominator produces nominal FAR values of 11.20 and 9.90. International Square’s nominal FAR is 13.1% higher despite its lower architectural height. No additional adjustment for the difference in site size is needed after that normalization.
International Square’s denominator is its record lot, which occupies 83.6% of the street-bounded square. The separate property at 1800 K Street NW is excluded. The Waterview’s denominator is its documented approved-project site; its hotel and condominiums occupy portions of the same second building rather than separate third and fourth buildings.
What the comparison supports—and its limits
The comparison demonstrates that visual height prominence does not reliably predict site-normalized floor-area density. Broad building coverage and linked volumes can accommodate substantial floor area without a tall skyline profile.
International Square uses DC assessment gross building area and an official record-lot denominator; The Waterview uses Arlington County approved-project area and site records. These source systems do not use a harmonized floor-area definition. The 13.1% gap is therefore a source-defined comparison rather than a certified zoning-FAR result. An approximately 12%–13% change in one reported-area numerator, or an equivalent denominator change, could eliminate the gap; the evidence does not establish that such a discrepancy exists.
This two-site result does not establish DC’s height regime as the sole cause of the buildings’ forms. Nor does it show that height reform cannot add usable capacity or improve light, views, use mix, public space, or feasibility. It establishes a narrower point: height and floor-area density must be measured separately.